None

call images

Call us

08061033553

Versa Control PneuGage-T7V

Versa Control PneuGage-T7V

Product Details:

  • Product Type Versa Control PneuGage-T7V
  • Usage Industrial
  • Frequency 50Hz Hertz (HZ)
  • Color Blue
  • Size Standard
  • Display Digital
  • Material Metal
  • Click to View more
X

Versa Control PneuGage-T7V Price And Quantity

  • 1 Piece

Versa Control PneuGage-T7V Product Specifications

  • Blue
  • Metal
  • Industrial
  • 50Hz Hertz (HZ)
  • Standard
  • Digital
  • Versa Control PneuGage-T7V

Versa Control PneuGage-T7V Trade Information

  • 10 Piece Per Month
  • 10 Days
  • All India

Product Description

Specification

Input Channels

1/2/3/4/5/6 Pneumatic

Applications

Standard/Honing

Dimension Type

Linear

Resolution

0.1m/ 1m

Units

mm

Measurement Modes

Current, Min, Max, TIR, AVG

Additional results

Max, Min, Ovality, and Taper for respective result can be display in run mode as additional results.

Result Formula Editor

Result formula can be edited for combinations of Piezo channels and / or other results.

Indications

Pass, Fail, Warning with facility to select require display reading in require colour according to the tolerance band

Grade

Max 25 Grades available

Other Features

Machine Stop Massage and Machine stop signal available for reject job condition

Calibration

Single/Double Master configurable

Force Mastering after N number of measured jobs.

Group Calibration for selected result in one group.

Auto Mastering is available. Accept Higher and Lower master on inserting into fixture/plug automatically in calibration process

Auto Air Cut-Off

Yes (Air will become ON after inserting job in Fixture/Plug) Air Saving facility. When nothing is inserted in Fixture/Plug Air will be OFF

Measurement process

Auto Cycle (After inserting job in Fixture/Plug it will show related Fixture/Plug result)

Measurement Cycle (Sequential measurement)

Charts

XBar- R Chart/ XBar- S Chart

Histogram

Runchart

Online SPC

Cp, Cpk, Pp, Ppk, Sigm

Counters

Over Size

Under Size

OK

Not Good

Total measure

Total produces (After receiving Cycle complete signal from Machine)

Setup

100nos can be created.

Number Of Results

32

Display

7 touchscreen Colour LCD display

Ports

1. RS-232 for PC communication

2.RS-232 for machine interface (compatible Fanuc o-i Power mate/16/18 series)

USB

USB2.0 Compliant (For Mass Storage Device).

Ethernet

Ethernet for sending reports to server using Client server utility

Digital Outputs

7 outputs, Isolated, Open collector

Digital Inputs

8 Inputs, Isolated

Display Views

Digital Readout/ Dial / Run Chart

Memory

In built micro SD card of 4GB for data storage (Contact manufacturer for additional storage capacity)

Footswitch interface

Available

Login

Operator and Supervisor login (Limited menu access to operator)

Report Storage

Shift wise data storage

Report Transmission

LAN/ WI-FI (Need to purchase WI-FI Dongle)/ USB

Report Format

PDF, CSV, and DFQ (to view in Q-DAS application).

In PneuGage we can only view PDF format file.

Technical Details 

Enter Buying Requirement Details
Email Id
Mobile number

Other Products in 'Electronic Gauging equipments' category



Back to top